Información técnica
| Estado del artículo |
Nuevo |
| Nombre del fabricante |
Switch actuator REG-K/2x230/16 w. manual mode and current detection, light grey |
| Marca |
Schneider Electric
|
| Categorías |
Dispositivos de bus KNX/Modbus
|
| País de origen* |
DE |
|
* El país de origen real puede variar según el lote de suministro.
Para confirmar el país de origen concreto, póngase en contacto con su gestor de cuenta.
|
| Código del Sistema Armonizado |
8537 1098 00
|
| ETIM |
EC001097
|
| Sistema de bus KNX |
Sí |
| Con comunicación por bus |
Sí |
| Sistema de bus LON |
No |
| Sistema de bus inalámbrico KNX |
No |
| Radio bidireccional |
No |
Detalles del embalaje
| Nivel de embalaje 1 |
3606485100050 |
| Nivel de embalaje 2 |
3606485100058 |
Otros datos técnicos
| Tipo de fijación |
DRA (adaptador para carril DIN) |
| Corriente nominal |
16 A |
| Potencia de salida |
3600 W |
| Tensión nominal de funcionamiento |
230 V |
| Sistema de bus inalámbrico |
No |
| Sistema de bus Powernet |
No |
| Potencia máx. de conmutación |
3600 W |
| Número máx. de contactos de conmutación |
2 |
| Número de entradas digitales |
0 |
| Ancho en módulos |
2.5 |
| Corriente de conmutación máx. |
16 A |
| Apto para carga C |
Sí |
| Posibilidad de conectar fases diferentes |
Sí |
| Manejo local/manual |
Sí |
| Grado de protección (IP) |
IP20 |
| Con indicador LED |
No |
| Ampliable modularmente |
No |
| Módulo de bus desmontable |
No |
| Profundidad mín. de la caja empotrada |
0 mm |
| Indicador de potencia LED máx. |
0 W |
Descargas
Descripción
For independent switching of loads via make contacts. The actuator has integrated current detection that measures the load current on each channel. All 230 V switch outputs can be operated with manual switches. With integrated bus coupling unit. A green LED indicates that the device is ready for operation once the application has been loaded. The load is connected with screw terminals. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. a data rail is not necessary. Operation as break contact or make contact. Staircase lighting function with/without manual OFF function and switch-off warning. Delay functions. Scenes. Logic function. Blocking or priority control. Feedback function. Status. Central function with delay. Parameterisation for bus voltage failure and recovery. Behaviour for download. Current detection function: Behaviour when value exceeds/falls short of the threshold value. Energy, operating and switch on counter with limit value monitoring. Flash function. Nominal voltage: 230 V AC, 50-60 Hz. DC 12-24 V ±10%, 0.1-16 A. For each switching contact: Switching current: 16 A, cos Phi 0.6. AC1 operation: max. 16 A. AC3 operation: max. 10 A. AC5 operation: max. 16 A. DC current switching capacity: max. 16 A/ 24 V DC. Output life endurance: Mechanical: