Información técnica
| Estado del artículo |
Nuevo |
| Nombre del fabricante |
residual current circuit breaker ID - 4 poles - 125 A - class B 500 mA |
| Marca |
Schneider Electric
|
| Categorías |
Interruptores diferenciales (RCCB)
|
| País de origen* |
DE |
|
* El país de origen real puede variar según el lote de suministro.
Para confirmar el país de origen concreto, póngase en contacto con su gestor de cuenta.
|
| ETIM |
EC000003
|
| Tipo de tensión |
AC |
| Corriente nominal |
125 A |
| Tensión nominal |
400 V |
| Tensión nominal de aislamiento Ui |
440 V |
| Número de polos |
4 |
| Corriente nominal de cortocircuito |
500 A |
| Tipo de corriente residual |
B |
| Protección selectiva |
No |
| Capacidad de corte en cortocircuito (Icw) |
10 kA |
| Corriente de impulso |
3 kA |
| Desconexión con retardo breve |
No |
| Frecuencia |
50/60 Hz |
| Tensión nominal soportada a impulsos Uimp |
4 kV |
Detalles del embalaje
| Nivel de embalaje 1 |
3303430167662 |
| Nivel de embalaje 2 |
3303430167660 |
Otros datos técnicos
| Tipo de fijación |
Carril DIN |
| Profundidad de montaje |
44 mm |
| Grado de contaminación |
3 |
| Ancho en módulos |
4 |
| Protegido contra explosiones |
No |
| Grado de protección (IP) |
IP20 |
| Sección de conexión para conductores rígidos |
1.5-50 mm² |
| Sección de conexión para conductores multifilares |
1.5-35 mm² |
| Con dispositivo de bloqueo |
Sí |
| Temperatura ambiente durante el funcionamiento |
-25-40 °C |
| Admite equipamiento adicional |
Sí |
Descargas
Descripción
This Acti9 RCCB-ID product is a residual current circuit breaker (RCCB). It is a 4P circuit breaker with 125A In rated current, 500mA earth leakage sensitivity and B type protection class. This product protects against electrical shock by indirect contact and fire hazards. The RCCB-ID B type residual current circuit breakers provide specific protection of three phase installations and people. The Acti9 RCCB-ID ensures protection in all industrial and tertiary buildings. This product is compliant with IEC 61008, EN 61008 and VDE 0664 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1250A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has an electrical endurance going up to 2000 cycles and a mechanical endurance going up to 5000 cycles. The Ue rated operational voltage is 230VAC or 400VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz or 60Hz. The width in 9mm pitches is 8. The product colour is light grey (RAL7035). The dimensions are (W) 72mm x (H) 86mm x (D) 76mm. The weight is 450g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 85°C.