| Estado del artículo | Nuevo |
| Nombre del fabricante | residual current circuit breaker ID - 4 poles - 125 A - class B 300 mA |
| Marca | Schneider Electric |
| Categorías |
Interruptores diferenciales (RCCB)
|
| País de origen* | DE |
| * El país de origen real puede variar según el lote de suministro. Para confirmar el país de origen concreto, póngase en contacto con su gestor de cuenta. | |
| ETIM | EC000003 |
| Tipo de tensión | AC |
| Corriente nominal | 125 A |
| Tensión nominal | 400 V |
| Tensión nominal de aislamiento Ui | 440 V |
| Número de polos | 4 |
| Corriente nominal de cortocircuito | 300 A |
| Tipo de corriente residual | B |
| Protección selectiva | No |
| Capacidad de corte en cortocircuito (Icw) | 10 kA |
| Corriente de impulso | 3 kA |
| Desconexión con retardo breve | No |
| Frecuencia | 50/60 Hz |
| Tensión nominal soportada a impulsos Uimp | 4 kV |
| Nivel de embalaje 1 | 3303430167648 |
| Nivel de embalaje 2 | 3303430167648 |
| Tipo de fijación | Carril DIN |
| Profundidad de montaje | 44 mm |
| Grado de contaminación | 3 |
| Ancho en módulos | 4 |
| Protegido contra explosiones | No |
| Grado de protección (IP) | IP20 |
| Sección de conexión para conductores rígidos | 1.5-50 mm² |
| Sección de conexión para conductores multifilares | 1.5-35 mm² |
| Con dispositivo de bloqueo | Sí |
| Temperatura ambiente durante el funcionamiento | -25-40 °C |
| Admite equipamiento adicional | Sí |
This is a Acti9 RCCB-ID residual current circuit breaker (RCCB). It is a 4P circuit breaker with In rated current of 125A, B type protection class and a 300mA earth leakage sensitivity. This product protects against electrical shock by indirect contact and fire hazards. The RCCB-ID B type residual current circuit breakers provide specific protection of three phase installations and people. The Acti9 RCCB-ID ensures protection in all industrial and tertiary buildings. This product is compliant with IEC 61008, VDE 0664 and EN 61008 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1250A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The electrical endurance is up to 2000 cycles. The mechanical endurance is up to 5000 cycles. The Ue rated operational voltage is 230VAC or 400VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz or 60Hz. The width in 9mm pitches is 8. The product colour is light grey (RAL7035). The dimensions are (W) 72mm x (H) 86mm x (D) 76mm. The weight is 450g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 85°C.