Regístrese para desbloquear sus precios B2B exclusivos y empezar a comprar. ¡Regístrese ahora!
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 1
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 2
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 3
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 4
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 5
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 6
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 7
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 8
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 9
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 10
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 11
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 12
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 13
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 14
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 15
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 16
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 17
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 18
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 19
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 20
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 21
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 22
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 image 23
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 1
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 2
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 3
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 4
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 5
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 6
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 7
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 8
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 9
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 10
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 11
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 12
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 13
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 14
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 15
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 16
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 17
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 18
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 19
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 20
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 21
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 22
NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1 thumbnail 23

NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1

Solo bajo pedido
EAN: 4015081779802
MPN: 183053
Embalaje: 1
Precio (sin IVA)
276,04 €
por unidad
Cantidad mínima de pedido: 1
Tiempo de entrega a nuestro almacén: 4-6 weeks
Este precio es válido hasta la siguiente lista de precios o hasta agotar existencias

Información técnica

Estado del artículo Nuevo
Nombre del fabricante NH fuse-switch 3p flange connection M10 max. 150 mm², busbar 60 mm, light fuse monitoring, NH1
Marca EATON
Categorías Fuse Switch Disconnectors
País de origen* DE
* El país de origen real puede variar según el lote de suministro. Para confirmar el país de origen concreto, póngase en contacto con su gestor de cuenta.
Código del Sistema Armonizado 8538 9099 00
ETIM EC001040
Corriente nominal permanente Iu 250 A
Número de polos 3
Grado de protección (IP), frontal Otros
Apto para fusibles NH1
Versión como interruptor principal No
Versión como interruptor de seguridad No
Potencia nominal de funcionamiento en AC-23, 400 V 0 kW
Tensión nominal de funcionamiento máx. Ue AC 690 V

Detalles del embalaje

Nivel de embalaje 1 4015081779802

Otros datos técnicos

Entrada de cable Otros
Corriente nominal condicional de cortocircuito Iq 120 kA
Accionamiento motorizado integrado No
Tipo de conexión eléctrica del circuito principal Conexión por tornillo
Versión como dispositivo de parada de emergencia No
Tipo de elemento de mando Asa de tapa
Corriente nominal soportada de corta duración Icw 6 kA
Apto para montaje en suelo No
Apto para montaje frontal No
Apto para montaje en barras colectoras Sí
Con protección contra conexión incorrecta Sí
Accionamiento motorizado opcional No
Posición del elemento de mando Parte frontal
Equipado con conectores enchufables No