Información técnica
| Estado del artículo |
Nuevo |
| Nombre del fabricante |
RS485 bus communication interface |
| Marca |
ELTAKO
|
| Categorías |
Dispositivos de bus KNX/Modbus
|
| País de origen* |
CN |
|
* El país de origen real puede variar según el lote de suministro.
Para confirmar el país de origen concreto, póngase en contacto con su gestor de cuenta.
|
| Código del Sistema Armonizado |
8526 9200 00
|
| ETIM |
EC002466
|
| Sistema de bus KNX |
No |
| Sistema de bus inalámbrico |
Sí |
| Otros sistemas de bus |
Otros |
| Sistema de bus inalámbrico KNX |
No |
| Radio bidireccional |
Sí |
Detalles del embalaje
| Nivel de embalaje 1 |
4010312315651, 4010312315651 |
| Nivel de embalaje 2 |
4010312315651 |
| Nivel de embalaje 3 |
4010312315651 |
Otros datos técnicos
| Tipo de fijación |
DRA (adaptador para carril DIN) |
| Sistema de bus Powernet |
No |
| Tipo de fijación |
Fijación por abrazadera |
| Ancho en módulos |
2 |
| Sistema de bus LON |
No |
| Grado de protección (IP) |
IP20 |
| Número de puntos de conmutación |
10 |
Descargas
Descripción
FTS14 communication interface for the Eltako RS485 bus with enclosed power supply FSNT14-12V/12W. Only 0.4 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Supply voltage 12V DC. Connection to the Eltako RS485 bus. Bus wiring and power supply with jumpers. The delivery includes 1 power supply FSNT14-12V/12W, 1 spacer DS14, 2 terminators with printing Ω, 1/2 module, 3 jumpers 1 module (including 1 spare), 1 jumper 1,5 TE, 2 jumpers 1/2 module (including 1 spare) and 1 jumper installation tool SMW14. If the power supply is subjected to a load of more than 4W, a ventilation distance of ½ to neighboring devices must be maintained on the left side. With a load greater than 6W, a ½ ventilation gap is also required between the FSNT14 and the FAM14 with the DS14 spacer. A DS14 spacer and a long jumper are therefore included. If the total power requirement of a series 14 bus system is higher than 10W, an additional FSNT14-12V/12W must be used for every 12W of additional power. Optionally, 12V DC can also be supplied at the GND/+12V terminals. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. The attached second terminator should be plugged to the last actuator. Mini USB to connect to a PC, to create an equipment list, to configurate the actuators using the PC tool PCT14 and for data backup. A legalization code to download the PCT14 from the Eltako homepage www.eltako.de is included in the FTS14KS. All FTS14EM and if needed gateways FGW14 will be connected to the terminal Hold when they connect a PC with a RS232 bus. According to the operating manual 10 different operating modes can be set with the operating mode rotary switch BA. The bottom LED lights up green if a connection from the PC tool PCT14 was created. When reading or writing date the LED flashes green. The green LED goes out if the connection from the PC tool PCT14 was terminated.