Regístrese para desbloquear sus precios B2B exclusivos y empezar a comprar. ¡Regístrese ahora!
Self-learning mains disconnection relay, 1 NO contact 10A image 1

Self-learning mains disconnection relay, 1 NO contact 10A

Solo bajo pedido
EAN: 4010312203477
MPN: 61100530
Embalaje: 1
Precio (sin IVA)
53,50 €
por unidad
Cantidad mínima de pedido: 1
Tiempo de entrega a nuestro almacén: 2-4 weeks
Este precio es válido hasta la siguiente lista de precios o hasta agotar existencias

Información técnica

Estado del artículo Nuevo
Nombre del fabricante Self-learning mains disconnection relay, 1 NO contact 10A
Marca ELTAKO
Categorías Interruptores generales
País de origen* CN
* El país de origen real puede variar según el lote de suministro. Para confirmar el país de origen concreto, póngase en contacto con su gestor de cuenta.
Código del Sistema Armonizado 8536 5080 00
ETIM EC001651
Corriente nominal 10 A
Tensión nominal 250 V
Frecuencia nominal 50 Hz
Corriente pico de conexión 20 mA
Supervisión de tensión DC

Detalles del embalaje

Nivel de embalaje 1 4010312203477, 4010312203477
Nivel de embalaje 2 4010312203477
Nivel de embalaje 3 4010312203477

Otros datos técnicos

Tipo de fijación Otros
Profundidad de montaje 26 mm
Ancho en módulos 0
Corriente máx. de conmutación (cos phi = 0,6) 10 A
Carga máx. de lámparas incandescentes 1000 W
Carga máx. de lámparas fluorescentes 1000 VA
Carga máx. de lámparas fluorescentes (circuito doble) 1000 VA
Carga máx. de lámparas fluorescentes (compensación en paralelo) 500 VA
Grado de protección (IP) IP20

Descargas

Descripción

1 NO contact not potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamp load 1000W. Standby loss 0.8 watt only. Built-in device for installation. 45mm long, 45mm wide, 26mm deep. 230V supply voltage and switching voltage. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The FR61-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring. Small loads up to 20mA are acceptable and, once major loads are disconnected, they do not prevent field disconnection. There is no need to manually set the limit. It is learned by the FR61. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected. As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial. A DC voltage of 230V DC with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure. When a load is turned on, the mains disconnection relay connects the phase. If the phase is switched on for the first time and after a power failure the FR61 automatically learns in again: At first an inrush current of 30mA is specified. If a new small load is switched on for more than 24 hours, the total current drawn by the monitored circuit is less than 200mA, and in the meantime the light has been switched on and off, the new load is learned in and the conductor is switched off. This learn-in mode can be realised immediately after connection of the new load by briefly switching off the MCB.