Información técnica
| Estado del artículo |
Nuevo |
| Nombre del fabricante |
Self-learning mains disconnection relay, 1 NO contact 16A |
| Marca |
ELTAKO
|
| Categorías |
Interruptores generales
|
| País de origen* |
CN |
|
* El país de origen real puede variar según el lote de suministro.
Para confirmar el país de origen concreto, póngase en contacto con su gestor de cuenta.
|
| Código del Sistema Armonizado |
8536 5080 00
|
| ETIM |
EC001651
|
| Corriente nominal |
10 A |
| Tensión nominal |
230 V |
| Frecuencia nominal |
50 Hz |
| Corriente pico de conexión |
20 mA |
| Supervisión de tensión |
DC |
Detalles del embalaje
| Nivel de embalaje 1 |
4010312203255, 4010312203255 |
| Nivel de embalaje 2 |
4010312203255 |
| Nivel de embalaje 3 |
4010312203255 |
Otros datos técnicos
| Tipo de fijación |
Carril DIN |
| Profundidad de montaje |
26 mm |
| Ancho en módulos |
3 |
| Corriente máx. de conmutación (cos phi = 0,6) |
16 A |
| Carga máx. de lámparas incandescentes |
2300 W |
| Carga máx. de lámparas fluorescentes |
500 VA |
| Carga máx. de lámparas fluorescentes (circuito doble) |
1000 VA |
| Carga máx. de lámparas fluorescentes (compensación en paralelo) |
500 VA |
| Grado de protección (IP) |
IP20 |
Descargas
Descripción
1 NO contact not potential free 16A/250V AC. Self-learning. 230V LED lamps up to 200W, incandescent lamp load 2300W. Standby loss 0.8 watt only. Modular device for DIN EN 60715 TH35 rail mounting. 1 module = 18mm wide and 58mm deep. 230V supply voltage and switching voltage. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The FR12-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring. Small loads up to 200mA, are acceptable and, once major loads are disconnected, they do not prevent field disconnection. The limit is taught-in automatically by the FR12 using a patented method so you need not set the limit manually. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected. As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial. A DC voltage with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure. When a load is turned on, the mains disconnection switch connects the monitored phase after approx. 1 sec and the LED lights red.