Información técnica
| Estado del artículo |
Nuevo |
| Nombre del fabricante |
RS485 bus multiple gateway with USB-A connection |
| Marca |
ELTAKO
|
| Categorías |
Dispositivos de bus KNX/Modbus
|
| País de origen* |
CN |
|
* El país de origen real puede variar según el lote de suministro.
Para confirmar el país de origen concreto, póngase en contacto con su gestor de cuenta.
|
| Código del Sistema Armonizado |
8526 9200 00
|
| ETIM |
EC001099
|
| Tipo de fijación |
DRA (adaptador para carril DIN) |
| Modelo |
Varias interfaces |
| Sistema de bus KNX |
No |
| Sistema de bus Powernet |
No |
| Ancho en módulos |
1 |
| Otros sistemas de bus |
No |
Detalles del embalaje
| Nivel de embalaje 1 |
4010312316054, 4010312316054 |
| Nivel de embalaje 2 |
4010312316054 |
| Nivel de embalaje 3 |
4010312316054 |
Otros datos técnicos
| Tipo de tensión |
DC |
| Potencia absorbida |
0.3 W |
| Sistema de bus inalámbrico |
Sí |
| Sistema de bus LON |
No |
| Protección contra desmontaje |
No |
| Interfaz de radio |
No |
| Interfaz IR |
No |
| Protocolo |
Otros |
| Dependiente del proveedor |
No |
| Actualizable |
No |
| Visualización |
No |
| Servidor web |
No |
| Tensión de funcionamiento |
5 V |
| Grado de protección (IP) |
IP20 |
| Con indicador LED |
No |
| Sistema de bus inalámbrico KNX |
No |
| Radio bidireccional |
No |
Descargas
Descripción
Multiple gateway with USB-A connection. Bidirectional. Only 0.3 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. The gateway is only 1 module wide but has multiple uses: To connect a Professional Smart Home controller or PC via a USB interface, to couple up to three FEM devices, for connection to the bus components of the older Series 12 or as a bus connector of two RS485 buses of Series 14. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. Operation in conjunction with FAM14 or FTS14KS. The Hold terminal is connected to the FAM14 or the FTS14KS. The PC is connected via a USB interface running at 9600 baud or 58 kbaud. Wireless receiver modules FEM are connected in parallel to the sub-bus terminals RSA2 and RSB2 as well as the power supply terminals GND and +12V. Up to 10 pushbutton input modules FTS12EM can be connected in series to the sub-bus terminals RSA2 and RSB2. If necessary in series with wireless receiver modules FEM. The Professional Smart Home controller or PC connection is via connection to the terminals Tx and Rx. Series 12 actuators are connected to the sub-bus terminals RSA2 and RSB2. There is no Hold connection in this case. A second Series 14 bus is fed into the terminals RSA2/RSB2. The settings of the operating mode rotary switch BA are carried out as described in the operating instructions.