Regístrese para desbloquear sus precios B2B exclusivos y empezar a comprar. ¡Regístrese ahora!
RS485 bus actuator 4-channel impulse switch with integrated relay function for LED image 1

RS485 bus actuator 4-channel impulse switch with integrated relay function for LED

Solo bajo pedido
EAN: 4010312317006
MPN: 30014076
Embalaje: 1
Precio (sin IVA)
66,24 €
por unidad
Cantidad mínima de pedido: 1
Tiempo de entrega a nuestro almacén: 4-6 weeks
Este precio es válido hasta la siguiente lista de precios o hasta agotar existencias

Información técnica

Estado del artículo Nuevo
Nombre del fabricante RS485 bus actuator 4-channel impulse switch with integrated relay function for LED
Marca ELTAKO
Categorías Dispositivos de bus KNX/Modbus
País de origen* CN
* El país de origen real puede variar según el lote de suministro. Para confirmar el país de origen concreto, póngase en contacto con su gestor de cuenta.
Código del Sistema Armonizado 8526 9200 00
ETIM EC001097
Sistema de bus KNX No
Con comunicación por bus Sí
Sistema de bus LON No
Sistema de bus inalámbrico KNX No
Radio bidireccional Sí

Detalles del embalaje

Nivel de embalaje 1 4010312317006, 4010312317006
Nivel de embalaje 2 4010312317006
Nivel de embalaje 3 4010312317006

Otros datos técnicos

Tipo de fijación DRA (adaptador para carril DIN)
Corriente nominal 16 A
Potencia de salida 400 W
Tensión nominal de funcionamiento 12 V
Sistema de bus inalámbrico Sí
Sistema de bus Powernet No
Potencia máx. de conmutación 1800 W
Número máx. de contactos de conmutación 4
Ancho en módulos 2
Otros sistemas de bus No
Apto para carga C Sí
Posibilidad de conectar fases diferentes No
Manejo local/manual No
Grado de protección (IP) IP20
Con indicador LED No
Ampliable modularmente Sí
Módulo de bus desmontable Sí
Indicador de potencia LED máx. 400 W

Descargas

Descripción

4-channel impulse switch with integrated relay function, 1 NO contact per channel up to 8A/250V AC, 230V LED lamps up to 400W, incandescent lamps 1800 watts, potential free from the power supply, with DX technology. Bidirectional. Only 0.1 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 2 modules = 36mm wide, 58mm deep. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. 230V LED lamps can be switched up to 400W and up to a maximum inrush current of 25A/100ms per NO contact. Patented Eltako Duplex technology allows you to switch normally potential free contacts in zero passage switching when 230V A/C voltage 50Hz is switched. This drastically ­reduces wear. To achieve this, simply connect the N conductor to the terminal (N) and L to K(L). This results in an additional standby consumption of only 0.1 watt. When all 4 relays of the F4SR14-LED are switched on, a power of 1 watt is required. If supply voltage fails, the device is switched off in defined mode. The channels can be taught-in as ES and/or ER channel separately from each other. Scene control: Several channels of one or several F4SR14-LED devices can be switched on or off in a scene by one of the four signals of a pushbutton with double rocker taught-in as a scene pushbutton. Central commands can be sent using a wireless pushbutton and/or with a Professional Smart Home controller. Use the rotary switches to teach-in the pushbuttons and test the 4 channels as required. For normal mode, the middle and lower rotary switches are then set to AUTO. With the upper rotary switch the EW time (0-120 seconds) is directly set for relays or the RV time (0-120 minutes) for impulse switches for all channels if necessary. If wireless motion/brightness sensors FBH (Master) and/or FBH (slave) are taught-in, the switching threshold will be set with the upper rotary switch, separated for each channel, at which the lighting will be switched on or off. Settings of the upper rotary switch in accordance with operating manual. When wireless brightness sensors are taught-in, define the switching threshold ­separately for each channel using the top rotary switch. The switching threshold switches the lighting on or off depending on the brightness (from approx. 0lux in position 0 to ­approx. 50lux in position 120). A hysteresis of approx. 300lux is permanently set for switch on/off. An additionally set RV time is not taken into account. Only one FBH (Master) or FAH can be taught-in per channel. However a FBH (Master) or FAH can be taught-in into several channels. When wireless window/door contacts FTK or window handle sensors FFG7B are taught-in, different functions can be set with the middle rotary switch in position AUTO 1 to AUTO 4 and linked to ­maximum 116 FTKs: AUTO 1 = window closed then output active. AUTO 2 = window open then output active. In settings AUTO 3 and AUTO 4 the FTKs taught-in to a single channel are linked automatically. With AUTO 3 all FTKs must be closed so that the N/O contact closes (e.g. for climate control). With AUTO 4 one open FTK is sufficient to close the N/O contact (e.g. for an alarm signal or to switch on the power supply for an extractor hood). One or several FTKs can be taught-in in several channels to allow several simultaneous functions in each FTK. After a power failure the link is restored by a new signal to the FTK and a signal on the next status message 15 minutes later. An additionally set RV time is not taken into account. Function with wireless smoke alarm detectors FRW or water sensors according to the operating instructions. The LED below the upper function rotary switch performs during the teach-in process according to the operating instructions. It shows control commands by short flickering during operation.