Información técnica
| Estado del artículo |
Nuevo |
| Nombre del fabricante |
Three-phase energy meter, MID approval |
| Marca |
ELTAKO
|
| Categorías |
Contadores de energía
|
| País de origen* |
CN |
|
* El país de origen real puede variar según el lote de suministro.
Para confirmar el país de origen concreto, póngase en contacto con su gestor de cuenta.
|
| Código del Sistema Armonizado |
9028 3019 00
|
| ETIM |
EC001506
|
| Tipo de fijación |
DRA (adaptador para carril DIN) |
| Ancho |
70 mm |
| Altura |
82 mm |
| Profundidad |
58 mm |
| Frecuencia |
50 Hz |
| Corriente máx. (Imax) |
80 A |
| Ancho en módulos |
4 |
| Grado de protección (IP) |
IP20 |
| Frecuencia de impulsos |
1000 Imp/kWh (kvarh) |
| Tipo de polos |
Cuatro conductores |
| Tensión nominal (Un) N-L |
230 V |
| Corriente nominal (In) |
10 A |
Detalles del embalaje
| Nivel de embalaje 1 |
4010312501634, 4010312501634 |
| Nivel de embalaje 2 |
4010312501634 |
Otros datos técnicos
| Modelo |
Medición directa |
| Apto para |
Consumo |
| Tipo de indicación |
Digital |
| Número total de dígitos (contador) |
7 |
| Tipo de contador |
Electrónico |
| Tipo de interfaz |
Otros |
| Tipo de energía |
Potencia activa |
| Tipo de tarifa |
Doble tarifa |
| Control de tarifa |
Externo |
| Mecanismo de disparo |
Sí |
| Calibrado |
Sí |
| Homologación |
Directiva de instrumentos de medida |
| Salida de impulsos |
Óptico |
| Tipo de impulso |
S0 |
| Clase de precisión |
B |
| Tipo de medición del perfil de carga |
No |
| Marcado EEC40 |
No |
| Con código de bloqueo |
No |
| Tensión nominal (Un) L-L |
400 V |
Descargas
Descripción
Maximum current 3x80A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With S0 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 40mA. The N terminal must always be connected. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Power consumption is shown by a bar flashing at a rate of 100 times per kWh. Designed as standard for using as double-tariff meter: Switch over to a second tariff by applying 230V to terminals E1/E2. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu according to the operation manual. First the background lighting switches on. The display then shows the total active energy per tariff, the active energy per resettable memory RS1 or RS2, and the instantaneous values of consumption, voltage and current per phase. Error message (false): When the phase conductor is missing or the current direction is wrong false and the corresponding phase conductor are indicated on the display.