Información técnica
| Estado del artículo |
Nuevo |
| Nombre del fabricante |
Acti9 iID - RCCB - 4P - 40A - 100mA - type AC |
| Marca |
Schneider Electric
|
| Categorías |
Interruptores diferenciales (RCCB)
|
| Código del Sistema Armonizado |
8536 3030 00
|
| ETIM |
EC000003
|
| Tipo de tensión |
AC |
| Corriente nominal |
40 A |
| Tensión nominal |
400 V |
| Tensión nominal de aislamiento Ui |
500 V |
| Número de polos |
4 |
| Corriente nominal de cortocircuito |
100 A |
| Tipo de corriente residual |
AC |
| Protección selectiva |
No |
| Capacidad de corte en cortocircuito (Icw) |
1.5 kA |
| Corriente de impulso |
0.25 kA |
| Desconexión con retardo breve |
No |
| Frecuencia |
50/60 Hz |
| Tensión nominal soportada a impulsos Uimp |
6 kV |
Detalles del embalaje
| Nivel de embalaje 1 |
3606480089305 |
| Nivel de embalaje 2 |
3606480089303 |
| Nivel de embalaje 3 |
3606480089305 |
Otros datos técnicos
| Tipo de fijación |
Carril DIN |
| Profundidad de montaje |
44 mm |
| Grado de contaminación |
3 |
| Ancho en módulos |
4 |
| Protegido contra explosiones |
No |
| Grado de protección (IP) |
IP20 |
| Sección de conexión para conductores rígidos |
1-35 mm² |
| Sección de conexión para conductores multifilares |
1-25 mm² |
| Con dispositivo de bloqueo |
Sí |
| Temperatura ambiente durante el funcionamiento |
-5-60 °C |
| Admite equipamiento adicional |
Sí |
Descargas
Descripción
This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 4P circuit breaker with 40A In rated current, 100mA earth leakage sensitivity and AC type protection class. This product protects against electrical shock by indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has an electrical endurance going up to 15000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 91mm x (D) 73.5mm. The weight is 0.37kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.